Line 1: Line 1:
 ====== Connection of a scale model servo ====== ====== Connection of a scale model servo ======
  
-{{ :servo.png?nolink& |Servo at Netzer playing field}}+<note important>For this functionality the **[[io_project|IO project]]** (base or pro) must be [[fwupdates|uploaded]] to Netzer.</note>  
 + 
 +{{ :servo.png?nolink& |Servo at Netzer playground}}
  
 The pulse outputs IO3 and SPI_INT can be directly connected to conventional [[wp>Servo_%28radio_control%29|scale model servos]].  The pulse outputs IO3 and SPI_INT can be directly connected to conventional [[wp>Servo_%28radio_control%29|scale model servos]]. 
Line 11: Line 13:
 At the Netzer, the settings should be carried out as shown in the figure (IO configuration page). At the Netzer, the settings should be carried out as shown in the figure (IO configuration page).
  
-{{ servoconfig.gif?nolink& |Servo configuration}}+{{ servoconfig.gif |Servo configuration}}
  
 The periodic time results from the internal 16-bit counter for continuous pulse signals: 65536\ *\ 400\ ns\ =\ 26,21\ ms. The periodic time results from the internal 16-bit counter for continuous pulse signals: 65536\ *\ 400\ ns\ =\ 26,21\ ms.